Purpose
Understand the closed control loop and fault categories.
Prerequisites
- Safe service state
Safety considerations
- Follow your site's lockout / isolation and robot-zone entry rules before approaching equipment.
- Only trained, authorized personnel perform service actions. This page is concept training.
- Drives can hold stored energy — follow isolation procedures.
Normal behavior
Following error small; no drive faults.
Conceptual operation
- Controller sends motion instruction → driver regulates current → motor moves → encoder feeds back → controller compares requested vs actual.
Inspection points
- Drive status indicators
Diagnostics
- Fault category: communication, encoder feedback, motor, overcurrent/overload, position mismatch, safety/interlock
Common symptoms
- Axis disabled
- Repeated faults under load
Recovery decision tree
1. Is it a feedback fault?
YES → Check encoder signal/cabling (authorized).
NO → Check load, mechanics and drive status.
Authorized procedure
INTERNAL / AUTHORIZED ONLY
Drive parameters and tuning values — available only in the model-specific, authorized SOP for your site. Not published on this website.
Verification
- Moves complete without faults
Escalation
Vendor support.